Reliability evaluation of non-isolated high gain interleaved DC-DC converter

Subbulakshmy Ramamurthi, Palanisamy Ramasamy

Abstract


A high gain DC-DC converter is the crucial part in renewable energy systems (RES) and in electric vehicular systems. The reliability of those high-gain converters needs to be assessed for the long-term operation of renewable energy systems. This article presents the reliability analysis of non-isolated high gain interleaved DC-DC converter. The analysis primarily relies on calculating the mean time between failures (MTBF). Based on military handbook (MIL-HDBK-217) criteria, the reliability calculation is performed. Stress factors and predicted failure rate for each component of presented converter is evaluated and tabulated. Reliability evaluation is performed for 1.5 kW hardware prototype. Based on reliability evaluation results, a reliable converter with better operating life time has been introduced.

Keywords


DC-DC converter; High gain; Interleaved and non-isolated; Mean time between failures; Reliability

Full Text:

PDF


DOI: https://doi.org/10.11591/eei.v13i2.6585

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

Bulletin of EEI Stats

Bulletin of Electrical Engineering and Informatics (BEEI)
ISSN: 2089-3191, e-ISSN: 2302-9285
This journal is published by the Institute of Advanced Engineering and Science (IAES) in collaboration with Intelektual Pustaka Media Utama (IPMU).