Harmonics mitigation technique for asymmetrical multilevel inverter fed by photovoltaic sources

Ali Riyadh Ali, Rakan Khalil Antar, Abdul Ghani Abdulrazzaq Abdulghafoor

Abstract


A multilevel inverter is an electrical device that converts a DC voltage into a higher AC voltage by generating a stepped waveform with several voltage levels. Unlike traditional inverters that produce a square wave or a pulse-width modulated (PWM) waveform with only two voltage levels, multilevel inverters can generate waveforms with three or more levels, resulting in reduced harmonic distortion, improved efficiency, and decreased electromagnetic interference. The design and control of multilevel inverters are active research areas that aim to enhance their performance, reliability, and scalability. In this research, a 31-level asymmetric cascaded multilevel inverter is suggested. The proposed multilevel inverter (MLI) system employs four photovoltaic cells as dc sources with structure of (1:2:4:8) Vdc. The system is modeled by MATLAB/Simulink and total harmonic distortion (THD) values of the output voltage and current are 1.106% for resistive load, and 1.35% and 0.403% for inductive load. These outcomes demonstrate the recommended circuit's efficacy and demonstrate its suitability for medium- and high-power applications.

Keywords


Boost converter; Harmonics; Maximum power point tracking; Solar energy; Total harmonic distortion

Full Text:

PDF


DOI: https://doi.org/10.11591/eei.v13i2.6607

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

Bulletin of EEI Stats

Bulletin of Electrical Engineering and Informatics (BEEI)
ISSN: 2089-3191, e-ISSN: 2302-9285
This journal is published by the Institute of Advanced Engineering and Science (IAES) in collaboration with Intelektual Pustaka Media Utama (IPMU).